Technical Details
Technical Detail:
Rubber Electrician Gloves (Rubber Insulating Gloves) are one of the most important hand safety items for the protection of electrical workers from any electrical shock while working around energized or live electrical systems.
In order to be safe and effective, the gloves must incorporate high dielectric and physical strength, along with flexibility and durability.
For superior performance they should meet the requirement of international standard and specification such as ASTM D120 or EN 60903.
Physical Requirement
Physical Requirements | |
---|---|
Tensile Strength Min. | 170.20 kg/cm² |
Tensile Strength at 200% MPa | 21(300) |
Ultimate Elongation min% | 800% |
Tear Resistance min kN/m | 21 |
Puncture Resistance kN/m | 18 |
Hardness max share | 47 |
Ageing Test
Designation of tests | ||
---|---|---|
Visual Inspections | Routine Tests | Sampling Test |
Length Thickness | YES | YES |
Bubbles Shape Outer Surfaces | YES | YES |
Spots marking and packing | YES | YES |
Mechanical Tests | ||
Tensile Strength | YES | |
Elongation at Break | YES | |
Puncture Resistance | YES | |
Tear Resistance | YES | |
Hardness Test | YES | |
Ageing Test | ||
Hot Air Ageing Test | YES | |
Flame Resistance | YES | |
Visual Inspection | ||
Length, Thickness, Shape, Outer Surface | ||
Marking and Packing |
Maximum Proof Test current leakage 7mA after conditioning the gloves in water for 16 hours.
168 hours at 70*C and not less than 80% of the unaged value. SATRA (United Kingdom)
Certifications
Test Reports
For good quality and to avoid from any skin allergy both the processes are of great importance. Our well equipped staff with technical know how focus on both the process with great care maintaining the temperature, time and the presence of any hydrophilic material in the gloves to bring good electrical resistance in Electrician gloves.
Selection of Raw Material
As we act upon the concept of TQM (total quality management) of modern technology era, therefore, great importance is attached in the selection of all kinds of basic raw materials involved in this manufacturing, We use Natural and Synthetic latex Rubber of premium quality having maximum DRC dried rubber contents, good PH level, in accordance with ASTM D1076 for Rubber Concentrated, Ammonia Preserved, creamed and centrifuged Natural Latex (Cis 1, 4 Polyisoprene).
Compounding
The most sensitive part of the manufacturing is compounding with respect to the product, its usage and its chemical, Electrical and mechanical properties. We select all chemicals keeping in view the brands, chemical properties and their any side effects to human health and skin.
Vulcanising and Leaching Process
For good quality and to avoid from any skin allergy both the processes are of great importance. Our well equipped staff with technical know how focus on both the process with great care maintaining the temperature, time and the presence of any hydrophilic material in the gloves to bring good electrical resistance in Electrician gloves.
Checking and Quality Control
During the manufacturing process, thickness, length, weight is strictly measured to keep up quality. Any defective gloves having any pinhole, crater, spot, etc are removed from the production line. Those gloves which are declared OK by QC(quality checker) in the manufacturing process are sent for further visual inspection, electrical tests, and mechanical tests in the gloves testing laboratory under ASTM D120 or EN 60903. All the manufacturing and inspecting are documented using instruction by quality management system ISO 9001: 2000 Place.